Operations
15. Vacuum Inlets
The vacuum inlets serve as connecting points for
vacuum hoses.
16. Exhaust
Exhaust fumes contain carbon monoxide which is
an odorless and deadly poison that can cause
severe injury or fatality. DO NOT run this unit in an
enclosed area. DO NOT operate this unit where
the exhaust may enter any building doorway, win-
dow, vent, or opening of any type
17. Solution Outlets
The solution outlets are the connecting points for
the high pressure solution hoses. These outlets are
quick disconnects that allow hoses to be plugged
into the unit.
18. Solution Screen
The solution screen is located on the front of the
machine. The function of this screen is to trap
foreign particles from exiting the machine and
plugging the orifices of the cleaning tools. This
screen is part of the machine maintenance
cleaning.
19. Chemical Check Valve
The chemical check valve allows chemicals to
enter the system and travel in a singular direction
to the wand. The chemical check valve prevents
chemicals from traveling up-stream into the
solution system of the unit.
20. Water Inlet
This quick connect allows the water supply hose to
be connected to the unit.
21. Lubrication Cup
The lubrication cup allows lubricant spray to reach
the vacuum blower.
22. Solution Pressure Regulator
The pressure regulator sets the pressure of the
solution system. This spring loaded valve can be
adjusted up or down. The pressure is increased by
turning the valve clockwise or reduced by turning
the valve counter clockwise. (This valve must be
maintained in accordance with this manuals main-
tenance table.)
23. Flow Meter
The flow meter is a gauge to indicate how much
liquid chemical is being introduced in the water
system. The quantity can be increased by turning
the chemical flow knob counter clockwise.
24. Chemical Metering Valve
The chemical metering valve regulates the amount
of chemical that is injected into the system.
Clockwise rotation of the knob closes the valve.
Counter clockwise rotation opens the valve,
allowing more chemical to enter the system.
25. Chemical Prime Control Valve
This valve allows the chemical to circulate through
the chemical system with little or no restriction. It
also purges out air that may be trapped in the lines
and cavities of the chemical pump. By turning the
valve clockwise the injection system is enabled.
26. Flow Setup Valve
This valve allows solution to move through the
machine and chemical to be injected simulating the
cleaning process. This allows the operator to set
the chemical flow level without connecting tools to
the machine. It is also useful in troubleshooting.
86325860 PEAK GTX PROCHEM